Compliant with JIS, IEC, Bellcore test spec
Various connector type available
Low insertion loss
|
|
High reflection loss
Custom lengths available
High quality and competitive price
|
|
|
|
|
|
Telecommunication networks
Instrumentation
LAN/WAN
|
|
Data transmission
CATV
Active device termination
|
|
|
|
|
|
TEST ITEM |
TEST CONDITION |
RESULT |
SM |
MM |
PC |
SPC |
APC |
Optical Characteristics |
Insertion Loss(dB) Return Loss(dB) |
Light source 1.3§, 1.5§(LED) Light source 1.3§, 1.5§(LED) |
¡Â0.2 ¡Â45 |
¡Â0.2 ¡Â50 |
¡Â0.2 ¡Â60 |
¡Â0.3 - |
Mechanical Performance |
Vibration Impact Pull Test Durability |
10~55Hz, 1.5§ Amplitude 3 Directions, 2Hr each 1.5m Drop, 8 Times 4.5kg load More than 1,000 Times |
<0.2dB <0.2dB <0.2dB <0.2dB |
<0.2dB <0.2dB <0.2dB <0.2dB |
<0.2dB <0.2dB <0.2dB <0.2dB |
<0.2dB <0.2dB <0.2dB <0.2dB |
Environmental Performance |
Temperature Cycle Thermal Aging Humidity Cycle |
-40¡É~ +80¡É 10 Cycles +85¡É, 960 Hours +40¡É, 95% RH, 240 Hours |
<0.2dB <0.2dB <0.2dB |
<0.2dB <0.2dB <0.2dB |
<0.2dB <0.2dB <0.2dB |
<0.2dB <0.2dB <0.2dB |
|
|
|
|
|